The BMS in our MG only removes excess energy to bring the voltages closer together until the delta is below 110 mV, then it cuts off the charge. It’s a really shaky charge management system. My Chinese BMS for my LFP solar battery does a much better job.
View attachment 35130
Then, all the cells drop to 3.33V (both min and max) as soon as the BMS SOC reaches 99%, staying that way down to around 30%, where the voltage changes to 3.28V. After that, it gradually decreases until 10%, where it reaches 3.20V. Finally, it keeps dropping until it reaches 3.1V / 3.13V at 0% on the dashboard, which corresponds to about 4.5% of the BMS SOC.
View attachment 35131
I'm assuming that is the computers assessment of the remaining capacity in the graph, or is it battery load in kW?
As I've said previously, you can't fully charge an LFP cell at 3.4V, the internal resistance will beat you every time. A rapid charge to 3.6V, then drop back to 3.45V, and allow an active balancer to do its thing will get an LFP battery back to 100% quickly and improve the cell longevity.
Those a cell temps I doubt we would ever see over here, to drag the cell temps that low would require a very low freezing point coolant, and that is never a good conductor of heat if it's water based, I'm assuming that the ambient temp was very low when those reading were taken ... ah, yes, I see the figure of 9°C in the left bottom corner
A lot of those readings still don't make a lot of sense, 3.7% of 51kWh is only roughly 9kWh remaining, the specs quoted previously say the min cell voltage a dragged down to 2.5V, a voltage between 3.1V and 3.13V does not represent a cell that has been dropped that low, nor does battery voltage of 323V, an average cell voltage of 3.1V, which looks more like the terminal voltage divided by the number of cells, rather than an actual cell voltage reading to come up with a min and max cell voltage ......
T1 Terry
Is phone battery fundamentally any different than a car battery? Yes chemistry is different is this particular case, but everything else applies just as well.
As for the battery you linked, i see nothing wrong. Everything they say is correct. Even capacity comparisment is on point, if compared to lead acid, as typical lead acid 100Ah battery will have half of it's capacity usable, unless you want to kill your battery very quickly.
The only "shady" thing about this particular battery is very poor BMS; it can only deliver 0,5C charge/discharge rate, while 1C+ being way more common on quality units.
The low continuous charge and discharge rates are pointer to the evaded truth about how the 100Ah capacity was measured. If they were honest and up front, they would have also listed the load testing regime used to support the 100Ah claim. A 50Ah @ C1 testing capacity would deliver 100Ah at a 1 amp or less load down to a rested voltage of 2.5V per cell average (specs say 10V).
The next implied but not actually stated thing in the description rambling, up to 10 x parallel capable, so that suggests 1,000Ah capacity, but also suggests the continuous discharge capacity would be 10 x 50 amps ..... but read through it again, that is never mentioned. The truth of the matter is, even 10 x 100Ah batteries in parallel, still only have a spec of 50 amps .... if any battery has to handle even a 100 amp load for more than 5 secs, the internal BMS fuse will fail and signals to the manufacturer, that the battery failure was because the specified parameters were exceeded.
Just another bit of deception by omission, no mention of the cell type used in the construction of the battery. The specs say 14.6V 100 amp peak for 5 secs and continuous charge rate of 50 amps, 3.65V per cell if the cells are perfectly balanced ....... how much heat would be generated attempting to burn off 182 watts (50 amps x 3.65V as suggested, but not stated, voltage per cell)? How would you dissipate that sort of heat, even if you could fit 4 x resistor that size, inside the battery .......
Looking at the selling price of the battery, what are the chances the BMS has the ability to lower the charge current ..... and how would it with no connection to the charger?
With a cut off voltage of 14.6V, the chance of any one of the 4 cells to go over 4V is very high .......
What are the chances of a 100 amp load close to the 10V cut off, not pulling a weak cell below 0v, even for 5 secs ......
There is lot of parameter monitoring required to go into a proper BMS ...... and they won't fit inside a battery case that is already full of LFP cells .....
T1 Terry